Home - News - Professional data that the air compressor industry needs to keep in mind
Professional data that the air compressor industry needs to keep in mind
Editing time:2021-09-15       Number of views:338

The data that air compressors need to know is different for different air compressors. It is necessary to match the appropriate air compressor according to the specific use scenario. After understanding the basic data of this series of air compressors, it is better to purchase.


  1. The outlet temperature of the micro-oil screw air compressor head is below 85℃ for air-cooled machines and below 80℃ for water-cooled machines. High temperature tripping will occur if it exceeds 110℃;


  2, the vibration value of the screw air compressor's head: the vibration value of the main engine of the air compressor should be less than 7.5mm/s;


   3. The temperature difference between cooling water input and output is about 15 degrees. Too large or too small indicates that there is a problem with the cooling system. And the cooling water flow rate is 3.7 liters/sec or more;


  4. The ambient temperature of the air compressor is 0-40℃. Too high will cause the temperature of the host to be too high, and too low will cause difficulty in starting the air compressor;


  5. After the oil is separated, the exhaust oil content is about 1-5ppm (GA55-90 machine is only 2ppm), the general oil content in compressed air is: 3ppm;


  6, the computer board shows: the air filter pressure difference value is lower than -0.05ba, the filter element must be replaced;


  7. Air filter particles: 98% for 1 micron; 99.5% for 2 micron; 99.9% for 3 micron;


   8. The filter particles of the oil filter: 10μm; the filtration precision of the oil can reach 0.1μm;


  9. Generally, the differential pressure of the newly replaced oil is about 0.2bar; the maximum differential pressure of the oil and gas separator cannot exceed 0.8bar, and it should be replaced immediately if it exceeds;


  10, the flash point temperature of the air compressor oil is 200℃, and the freezing point is -20℃;


11.


A. The formula for calculating the gas output of the air compressor is:


   1 cubic meter of gas produced per 6KW;


  1 kilowatt gas production is 0.1633 m3


  B, 1) British horsepower (HP) (hp)=0.746KW=746W


  2) Metric horsepower (HP) (hp)=0.735KW=735W.


   (Usually use this unit to convert)


  12, oil: the initial pressure difference is ≤0.2mpa, the maximum working temperature is 120℃;


  Oil filter: The maximum working temperature is less than 120℃, and the maximum working pressure is 1.4-2.5mpa;


  Air filter: working temperature is less than 120℃, maximum working pressure: 1.4—1.5mpa


 


   Bones oil-free air compressors provide you with 100% oil-free water-lubricated air compressors.


Copyright © 2021 Shanghai Ganjian Machinery Co., Ltd. all rights reserved Shanghai ICP No. 13001203-2